Nokia CC100 Manuel d'utilisateur Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
CC100Master Bridge User’s Guide
Specify that if the built-in Telnet server, Web server, and SNMP agent is enabled or not and assign the port number
for the service.
System Log
By designating the Syslog server IP on the CC100, the CC100 will emit Unix-like Syslog events toward each server.
Please refer to RFC-3164 for SyslogSeverity’, used to denote the log level – digit ‘0’ to ‘7’ for different severity
levels:
0: EMERGENCY – log only severe events
1: ALERT
2: CRITICAL
3: ERROR
4: WARNING
5: NOTICE
6: INFO
7: DEBUG – log everything
For example, the CC100 will emit only ‘EMERGENCY’ events to Server with the IP address ‘192.168.1.111
according to the following setting.